S Plan Wiring Centre Connections
- Live In (From FCU) + Boiler Live (L) + Programmer Live (L) + CH & HW Valves (Grey)
- Earth
- Neutral
- Programmer CH (on) + Room Stat Live (1)
- Switched Live from Room Stat (3) + Central Heating Valve (Brown)
- Programmer HW (on) + Tank Stat Live (1)
- –
- Switched Live from the Tank Stat + Hot Water Valve (Brown)
- Boiler Pump Live (PL) + Pump Live (L)
- Boiler Switched Live (SL) + CH & HW Valves (Orange)
S Plan Tank Stat Wiring
Hot water tank thermostat connections for hot water temperature control for S Plan hot water systems.

- Live = L (1)
- Switched Live = SL (C)
S Plan Room Stat Wiring
Room temperature thermostat connections for room temperature control of the central heating system for S Plan central heating systems.

- Live = L (1)
- Neutral = N (2)
- Switched Live = SL (3)
S Plan Central Heating 2 Port Valve Wiring
Central heating valve connections, colours and wiring center termination numbers.

- Grey (Live) = 1
- Green/Yellow (Earth) = 2
- Blue (Neutral) = 3
- Brown = 5
- Orange = 10
S Plan Hot Water 2 Port Valve Wiring
Hot Water valve connections, colours and wiring centre termination numbers.

- Grey (Live) = 1
- Green/Yellow (Earth) = 2
- Blue (Neutral) = 3
- Brown = 8
- Orange = 10
S Plan Boiler Wiring
S Plan boiler wiring diagram and connections, with pump overrun, shown below first is the cable (function) followed by the terminal number of the wiring centre.

- Live = 1
- Earth = 2
- Neutral = 3
- Pump Live (PL) = 9
- Switched Live (SL) = 10
S Plan Programmer Wiring
S Plan central heating & hot water programmer wiring diagram and connections, shown below first is the cable (function) followed by the terminal number of the wiring centre.

- Live (L) = 1
- Earth (⏚) = 2
- Neutral (N) = 3
- CH (on) = 4
- HW (on) = 6
S Plan Power Connections
S Plan power supply wiring diagram, shown below first is the cable (function) followed by the terminal number of the wiring centre.

- Live = 1
- Earth = 2
- Neutral = 3
S Plan Wiring Diagram
Wiring diagram for S Plan central heating and hot water systems, with pump overrun.

Note: Some earths have been omitted for clarity. Always check and follow the manufactures instructions as it may differ.